FOR MODELS WITH CIRCUIT BOARD Loosen the cover screw on the s 1. ide of the unit and open cover. 2. Unplug ballast plug from end of lamp. 3. Loosen the wing nut on swivel bracket and rotate the swivel bracket clockwise. NOTE: When replacing the lamp, always wipe off lamp before installing. 4. Slide lamp out carefully and dispose of properly. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire Air Purifying System lamp once a year to maintain the lamp’s maximum

Скачали: 0   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

After the call for heat has been satisfied, the UV Aire unit will operate for 45 minutes then shut off. 1. Turn off power switch on the UV Aire unit and unplug the unit before doing any wiring. 2. Loosen the cover screw and open the unit cover. 3. Locate terminals 1-2 on the circuit board and remove the jumper wire. 4. Wire to terminals W, C and G into the fan center on the furnace. Refer to Diagram A for proper wiring. 5. Close the cover and secure with the cover screw. Then plug the UV Aire ba

Скачали: 0   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

Refer to the configurations chart below when making your selection. WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. Straight Angled Positions Exclusive 5 Position Mounting BestGood UV-Aire Configurations Standard 90. Installation (Flat Bracket) (16” Duct) Patent Pending Angle

Скачали: 1   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

(See Figure 15) 7. Remove tag and alcohol from lamp. Wipe off lamp being sure not to ouch lamp with bare hands. The oils from your hands will reduce lamp output. 8. Insert lamp through hole until lamp cannot be inserted any further. (See Figure 16) 9. Swing swivel bracket over end of lamp. Hand-tighten the wing nut on stud. (See Figure 17) Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened. 10. Plug ballast plug into end of lamp. (See Figure

Скачали: 0   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

**Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building. GENERAL INFORMATION The UV-Aire unit uses technology that is recommended by doctors who state that "ultraviolet radiation, properly integrated with heating, ventilating, and air conditioning systems, shows the most promise as a widely applicable means of air disinfection".1 Optional UVC-Light Shield: Designed to mount at virtually any angle to guard

Скачали: 0   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

Company will return repaired or replacement Product to customer in working condition. Labor charges are not covered as part of the limited warranty. 2. With regard to UV lamps/bulbs, customer shall be required to include a "valid proof of purchase" (sales receipt) identifying the Product purchased (Product model or accurate date code information) and the date the Product(s) was purchased. 3. Product whose warranty/quality stickers, Product serial number plates or electronic serial numbers have b

Скачали: 0   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

i. Remove the two hex nuts and angled bracket from included bagged hardware. ii. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 14) NOTE: Be sure to note location of lamp hole in bracket relative to unit base. 6. Mount the unit base to the duct using the four mounting screws provided. (See Figure 15) 7. Remove tag and alcohol wipe from lamp. Wipe off lamp being sure not to touch lamp with bare hands. The oils in your hands cause a reduction in lamp

Скачали: 0   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

GENERAL INFORMATION There are different size units available, depending on the square footage of your home. See chart below for determining your home’s needs. MODEL MINIMUM DUCT WIDTH VOLTS AMPS Hz WATTS MAx AIR TEMP .F LAMP INTENSITY AT 1 METER RECOMMENDED MAx. Sq. FEET UV-12C 9" 120 0.5 60 30 190. 37 .W/cm2 1500 UV-18C 14" 120 0.5 60 30 190. 73 .W/cm2 2000 UV-28C 22" 120 1.1 60 60 150. 105 .W/cm2 3000 UV-28 22" 120 1.1 60 60 150. 105 .W/cm2 3000 UV-12HP 9" 240 0.5 60 30 190. 37 .W/cm2 1500 UV-

Скачали: 9   Размер: 1 mb   Производитель: Field Controls  
Категория: Воздухоочистители
@name

n the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil. (See Figure 1) 2. Determine the type of duct you have. * Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units. **Packaged units are systems where the air handler and the air conditioning compressor are built together and are instal