When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 11. Penetrating the roof To maintain a 1" clearance to the pipe on a roof with a pitch, a rectangular opening must be cut. 1. Determine the center point through which the pipe will penetrate the roof. 2. Determine the center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6"

Скачали: 9   Размер: 1 mb   Производитель: Desa  
Категория: Камины
@name

4. An outside air kit is available with this fireplace (see Optional Outside Air Kit, page 6). MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 1/2" min.* Front of fireplace 48" min. Floor** 0" min. Perpendicular wall to opening 12" min. Top spacers 0" min. Mantel clearance see Mantels, page 5 Chimney outer pipe surface 1" min. * Not required at nailing flanges ** See step 2 of Framing WARNING: Do not pack requiredairspaceswithinsulation or other materials. Minimum/Maximum Chimney

Скачали: 8   Размер: 1 mb   Производитель: Desa  
Категория: Камины
@name

may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncombustible facing material, use only noncombustible mortar or adhesive. Optional Gas Line Installation Gas line hook up should be done by your supplier or a

Скачали: 7   Размер: 1 mb   Производитель: Desa  
Категория: Камины
@name

In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers. This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21.60, Z21.84 or RGA 2-72 standards or for use with a vent- free gas log heater approved to ANS Z21.11.2 standard. This wood burning fireplace complies with

Скачали: 3   Размер: 1 mb   Производитель: Desa  
Категория: Камины
@name

WARNING: If the fireplace has been used for wood burning, the firebox and chimney must be cleaned of soot, creosote and ashes by a qualified chimney cleaner. Creosote will ignite if heavily heated. WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position. Optional Gas Line Installation Continued Glass Door Installation IMPORTANT: Install glass door frame before installing gl

Скачали: 0   Размер: 1 mb   Производитель: Desa  
Категория: Камины
@name

WARNING: Use solid wood or processed solid fuel firelogs only. When processed wood fuel fire logs are used, do not poke or stir the logs while they are burning. Use only fire logs that have been evaluated for the application in fireplace and refer to fire log warnings and caution markings on packaging prior to use. WARNING: Always leave glass doors fully opened or fully closed when operating fireplace. 109493-01N Specifications 42" Models 10.5" 17" 0.625" 51" 30.5" 28.5" 21.25" 41.25" 23.5" 24.

Скачали: 0   Размер: 1 mb   Производитель: Desa  
Категория: Камины
@name

Chase installations Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. Terminations be separated a minimum of 24" center to center and stacked at a minimum vertical height difference of 18" (see Figure 16). Note: If a decorative shroud is to be installed, contact the manufacturer for specifications. Venting

Скачали: 3   Размер: 2 mb   Производитель: Desa  
Категория: Камины
@name

Secure in position by nailing through shingles (see Figure 13). DO NOT NAIL THROUGH FLASHING CONE. Installing Flashing on a Metal Roof When installing the flashing on a metal roof, it is required that putty tape be used between the flashing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal. Stor

Скачали: 5   Размер: 2 mb   Производитель: Desa  
Категория: Камины
@name

Position the retainer brackets at 8 3/4" apart from center to center of notch. Model Distance Apart GM36 3 1/4" Centers GM42 4 1/4" Centers GM50 8 3/4" Centers See Chart for Grate Retainer Brackets Location Figure 22 - Installing Grate Retainer Bracket Grouting instructions Material provided: 2 - 9 lb. bags of cement 2 - 9 lb. bags of sand Material required: 1 - Piping bag 1 - Joints striker 1 - Heavy duty mixing bucket 1 - Trowel 1. Moisten brick surface with a damp sponge or a spray bottle jus

Скачали: 1   Размер: 2 mb   Производитель: Desa  
Категория: Камины
@name

LINEAL GAIN PART NO. DESCRIPTION GAIN (IN) Georgian Fireplace 66 1/2" 12-12DM 12-12HT Pipe Section 10 5/8" 18-12DM 18-12HT Pipe Section 16 5/8" 24-12DM 24-12HT Pipe Section 23 5/8" 36-12DM 36-12HT Pipe Section 34 5/8" 48-12DM 48-12HT Pipe Section 46 5/8" RLT-12D RLT-12HT Round Termination 7 3/4"* STL-12D Square Chase-Top with Slip Section 7" to 15"* * The lineal gain for the terminations is measured to the flue gas outlet height. Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4"